Description of the indicator light status:
1. Work: the work indicator light indicates entering the operation mode, and the light out indicates standby.
2. Output: The output indicator light indicates that the load works, and the light goes out indicates that the load stops
working.
3. Timed on: the timing on indicator light indicates that the timing output is started.
4. Timing off: The timing off indicator light indicates that the timing off output is started
Second, the key:
Start on key, and close on key, when the running light turns on and after shutdown
light goes out.
"+" key (target temperature / validity temperature / timing opening time can be set)
1. With the work indicator light (on), press the "+" key to set the target temperature (0-200 degrees). The default value is 38.
2. When the work indicator light (on), press "+" for more than 3 seconds to set the validity temperature value (-20 to + 20
degrees), and the default value is 0.
3. In the case of pointing out the light (out), long press the "+" key for more than 3 seconds to set the timing of the open
output time (0-999 minutes), the default value is 0.
"-" key (return / timing time can be set)
1. Under the work indicator light (on), long press "" key for more than 3 seconds to set the difference temperature value (1-40
degrees). The default value is 5.
2. If the work indicator is illuminated (out), long pressing the "" key for more than 3 seconds can set the timing shutdown
output time (0-999 minutes), and the default value is 0.
Hold down the "+ -" key at the same time (you can set the high temperature alarm parameter / refrigeration LLL and heating HHH)
1. Under the working indicator light (on), holding down the "+ -" button for more than 3 seconds can set the high temperature
alarm parameter. The adjustment range is 0-15 and the default is 0 no alarm. For example, if set to 10, then the temperature
of 10 degrees above the stop temperature will have a warning sound, the code prompt (H1).
2. In the case of the working indicator light (out), the "+ -" button can set the cooling and heating mode. The default mode is
the heating mode HHH.
Code prompt:
1. Display E1: Sensor fault prompt.
2. Display H1: high temperature alarm warning.