P0-0, P0-1, P0-2 and three modes have alarm prompt function. For example: When the value of P0-0 is set to 25, the product will enter 25 seconds
After 25 seconds, the bee tweezer will make a sound of "Dididi" and continue to ring for 30 seconds.
Although we have this function, we need to contact us to send this version.
P0--0: T1 timing mode is seconds
P0--1: T1 timing mode is minute
P0--2: T1 timing time mode is when
P1--0: The relay pulls in after a delay of T1 time (T1 timing)
P1--1: The relay is released after a delay of T1 time (T1 timing)
P1--2: After delaying T1 time, the relay pulls in (T1 timing), and after delaying T2
time, the relay releases (T2 timing), and it ends.
P1--3: After delaying T1 time, the relay is released (T1 timing), and after delaying T2
time, the relay pulls in (T2 timing), and it ends.
P1--4: The relay pulls in after a delay of T1 time (T1 timing), and the relay is
released after a delay of T2 time (T2 timing), repeating the cycle.
P1--5: The relay is released after a delay of T1 time (T1 timing), and the relay is
pulled in after a delay of T2 time (T2 timing), and the cycle is repeated.For example, a
customer needs to turn on the machine for 10 seconds and turn it off for 20 seconds.
The settings are as follows:T1 set time 10, T2 set time 20
P0—0 (T1 timing range is seconds)
P1—5 (timer working mode is to work first and then stop to cycle)
Restoring to factory settings: The data is messed up due to wrong pressing of the
settings. If the settings cannot be set, choose to restore the factory settings, press
and hold SET and then power on.